Hardwired Smoke Alarm OEM/ODM Solutions for Residential, Apartment and Project Applications

The ultimate solution for wired smoke detectors for brand owners, engineering channel partners, and real estate project owners. For B2B buyers, a…

The ultimate solution for wired smoke detectors for brand owners, engineering channel partners, and real estate project owners.

For B2B buyers, a hardwired smoke alarm is not just an AC powered device. It is a project safety component that must match the target certification, building wiring, interconnect logic, installation method and long-term maintenance plan. If these items are not reviewed before sampling, the cost usually appears later as failed certification, field complaints, rework or unstable mass production.

From a manufacturing engineering perspective, the core value of hardwired smoke alarms lies in three points: stable main power supply, the ability to achieve whole-house/building-wide linkage, and suitability for mass installation in new residences, apartments, hotels, dormitories, and engineering projects. However, if it’s only understood as an “AC powered smoke alarm,” it’s easy to leave hidden problems in certification, structure, power supply, linkage, and installation.

Why B2B Buyers Choose Hardwired Smoke Alarm OEM/ODM Solutions

For brand owners, distributors and project contractors, hardwired smoke alarms are not only AC powered devices. They are part of a project safety system that must meet certification, wiring, interconnection, installation and long-term maintenance requirements.

1. UL Standard Updates Increase R&D and Compliance Pressure

    According to UL’s official statement, the new generation of smoke alarm/detector standards has undergone more than 250 revisions, with a focus on adding polyurethane foam fire and cooking false alarm testing. The aim is to ensure that products can respond to modern home fires while reducing nuisance alarms.

    2. False Alarm Control Has Become a Certification and After-Sales Issue

    In 2024, UL Solutions stated that one of the updates to UL 268 and UL 217 is to reduce nuisance alarms caused by cooking, while also addressing the characteristics of fire smoke in modern residential and commercial environments; UL is also expanding its smoke sensitivity testing capabilities in Suzhou, China, to help manufacturers complete R&D verification more quickly.

    3. Project Applications Require Standardized Wiring, Interconnection and Batch Maintenance

    CFS provides examples in its project solutions: an 80-apartment complex requires approximately 4 smoke alarms, a 300-residence complex requires approximately 10, a factory can require up to 72, and a hotel project can require up to 120. This demonstrates that hardwired smoke alarms are more suitable for newly built residences, apartments, hotels, schools, and other projects requiring unified wiring, unified linkage, and batch maintenance.

    For OEM/ODM buyers, these changes mean that product development should start from compliance planning, power architecture, false alarm control and mass production verification, not from housing appearance alone.

    What B2B Customers Check Before Buying Hardwired Smoke Alarms

    For B2B buyers, the real cost is not only the FOB price. The hidden cost usually comes from failed certification, field complaints, project rework and inconsistent quality between samples and mass production. Before buying or developing a hardwired smoke alarm, buyers should check three engineering points: power stability, compliance route and false alarm control.

    Hardwire Photoelectric Smoke Alarm factory CFS SM22
    Hardwire Photoelectric Smoke Alarm factory CFS SM22

    Stable AC Power and Battery Backup Performance

    Hardwired Smoke Alarms are typically connected to 120V/230V AC with a backup battery. Customers are not concerned with “whether it will light up,” but rather with:

    • Whether the backup battery will immediately take over in case of a main power failure;
    • Whether there will be false alarms, system crashes, or slow restarts during power switching;
    • Whether there will be missed alarms, delayed alarms, or false triggers when multiple alarms are linked;

    Compliance with NFPA 72, UL 268 and UL 217

    For new residential and construction projects, wired power supply, interconnected alarm systems, and backup power are often key considerations for project owners and acceptance inspectors.

    False Alarm Reduction in Real Installation Environments

    A false alarm of hard-wired smoke detectors can affect not just one household, but an entire apartment building, hotel floor, or property development. Common complaints include:

    • False alarms near the kitchen.
    • False alarms due to bathroom steam.
    • Dust entering the optical chamber is causing sensitivity to drift.
    • Strong airflow affecting the smoke entry path.

    Strong airflow may bring dust into the smoke chamber and increase false alarm risk. It may also disperse smoke before it reaches the sensing chamber. For this reason, installation guidance should clearly define the distance from kitchens, bathrooms, corners, air vents and other abnormal airflow locations.

    Why Hardwired Smoke Alarm Projects Fail After Sampling

    Hardwired as “adding an AC power module”

    This is a common design pitfall. Hardwired smoke detectors are not as simple as adding an AC-DC module to a regular battery-powered alarm. They involve:

    • AC input protection.
    • AC-DC power efficiency.
    • Low-power standby management.
    • Backup battery switching logic.
    • Low battery voltage detection.
    • EMC/surge/voltage withstand design.
    • Safe distances between wiring terminals.
    • Structural strength of the mounting base.
    • Interference immunity of linkage signals.

    If the power architecture is not designed for certification and mass production, it may work well at the prototype stage, but problems (long-term power-on, high and low temperature cycling, and on-site wiring) will become apparent during mass production.

    custom fire alarm supplier CFS

    Photoelectric Chamber and Algorithm Not Optimized for False Alarm Control

    Most mainstream residential smoke alarms currently use photoelectric detection principles.  An infrared emitter emits a beam of light into an optical cavity; in normal air, the signal at the receiver is low. When smoke particles enter the cavity, the light is scattered, amplifying the receiver signal. The MCU (Microcontroller Unit) then determines whether to trigger an alarm based on changes in smoke concentration, duration, and a threshold algorithm.

    UL’s requirements for modern smoke detectors go beyond simply “being able to sound”; they require products to distinguish between different fire types and interference sources. UL states that products under the new standard may use more advanced sensors, multiple sensors, or algorithms to differentiate between smoldering fires, open flames, and cooking aerosols based on differences in smoke particle size, quantity, gas concentration, and color.

    OEM/ODM Projects Without Mass Production Consistency Control

    Many B2B customers initially received samples that performed well, but after mass production, the following issues arose:

    • Batch-to-batch sensitivity variations;
    • Unstable buzzer sound pressure levels;
    • Poor PCB soldering consistency;
    • Rough edges and dust spots in the optical cavity;
    • Inaccurate low battery voltage detection;
    • Decreased interconnection signal distance and anti-interference capability.

    The root cause is not “workers being careless,” but rather the lack of a complete engineering verification and mass production control chain in the ODM project. Smoke alarms are safety products and cannot rely solely on final inspection and sampling; control must be implemented from the structure, sensor, PCB, firmware, calibration, aging, packaging, and traceability system.

    Risk Points

    Issues

    Root Causes

    Consequences

    Inadequate AC Power Design

    Power failure, restart, false alarms

    insufficient verification of temperature rise, ripple, and EMC

    engineering complaints, rework

    Unstable Photoelectric Chamber

    False alarms or sensitivity drift

    inadequate design of smoke entry path, insect prevention, and dust prevention

    increased after-sales costs

    Weak Linkage Signal

    Multiple alarms out of sync

    unverified anti-interference and wiring distance

    project acceptance risks

    Poor Mass Production Consistency

    Good samples, inconsistent mass production batches

    lack of calibration, aging, and traceability

    decreased brand trust

    Missing Incorrect Wiring Protection

    Product damage, false trigger or no response

    Terminal design and protection circuit not verified

    Higher installation failure rate and field service cost

    CFS has OEM/ODM services covering sensor technology to brand implementation, providing end-to-end customization for 200+ global fire security brands, and UL, EN, AS, and CE design capabilities and systematic quality control.

    CFS Hardwired Smoke Alarm OEM/ODM Engineering Solution

    The following solution is more suitable for brand owners, distributors, real estate project developers, engineering channel partners, and private contract clients for developing their own brand of hardwired photoelectric smoke alarm, hardwired interconnected smoke alarm, hardwired Wi-Fi smoke alarm, or AC-powered smoke alarm with battery backup.

    ODM SMOKE DETECTOR factory CFS line
    ODM SMOKE DETECTOR factory CFS line

    Product Definition: Market, Certification and Installation Scenario

    Before initiating a project, we recommend that clients confirm 5 core parameters:

    Decision Items

    Issues B-end Customers Need to Confirm

    Engineering Impact

    Target Market

    US, Canada, Australia, UK, EU, or Middle East?

    Determines UL/EN/AS/CE/RCM pathway

    Power Supply

    120V AC, 230V AC, AC+Battery Backup, DC Supply?

    Determines power board, safety distance, and certification testing

    Connection Method

    Hardwired interconnect, RF interlink, Wi-Fi, Hardwire+RF?

    Determines communication architecture and interference immunity design

    Application Scenarios

    Apartments, residences, hotels, schools, rental properties?

    Determines sound pressure level, mounting base, and packaging instructions

    Brand Strategy

    Standard private label, customized structure, customized firmware, co-certification?

    Determines MOQ, NRE, development cycle, and BOM

    Power Supply Design: 120V/230V AC with Reliable Battery Backup

    Recommended features include:

    • AC mains power input;
    • Backup lithium or alkaline battery;
    • Power switching detection;
    • Low-voltage alarm logic;
    • MCU low-power management;
    • AC fault indication;
    • Power surge and overvoltage protection;
    • Terminal misconnection prevention structure.

    For project owners, backup batteries are not a marketing parameter, but an acceptance and maintenance parameter. One of the core principles of NFPA 72 is that fire alarm systems must remain operational even when the mains power supply fails. In multi-family buildings, hotels, and dormitories, backup power design must be incorporated into the system design from the outset, not as a last-minute fix.

    Hardwire AS 3786 Photoelectric Smoke Alarm factory CFS SM22
    Hardwire AS 3786 Photoelectric Smoke Alarm factory CFS SM22

    Manufacturing engineering focus:

    • AC-DC modules should not only be evaluated based on output voltage, but also on temperature rise, ripple, EMC, and long-term aging.
    • Backup batteries should not only be evaluated based on capacity, but also on matching quiescent current, alarm current, low-temperature performance, and storage life.
    • The low-battery threshold should be defined by real load testing, so the buzzer can still reach the required alarm output under low-voltage conditions.

    CFS can provide customized services supporting 3/5/7/10-year battery life, different battery voltage specifications, AC+Battery backup, and DC supply options, which are crucial for hardwired smoke alarm OEM/ODM projects.

    Detection Design: Photoelectric Smoke Chamber and Anti-False Alarm Algorithm

    For residential and apartment settings, photoelectric smoke alarms are better suited to identify visible smoke generated in the early stages of smoldering fires. Their basic working principle is: Infrared emission → Smoke particle scattering → Receiver signal change → MCU algorithm judgment → Buzzer/linkage alarm output.

    However, in ODM mass production, the following details truly affect performance:

    • Smoke entry path of the optical cavity;
    • Insect screen structure;
    • Infrared emission angle;
    • Receiver sensitivity;
    • Cavity material reflectivity;
    • PCB mounting position;
    • Software sampling frequency;
    • Multi-point threshold judgment;
    • Dust compensation;
    • Temperature and humidity adaptability.

    With updates to the UL 268/UL 217 standards, products must not only be sensitive to real fires but also reduce false alarms during cooking. UL Solutions points out that these standard updates are driving manufacturers to reduce nuisance alarms through new technologies and address fire smoke in modern residential and commercial environments.

    CFS recommends the following ODM design directions:

    • Employ a stable photoelectric sensing chamber;
    • Add insect-proof design;
    • Identify short-term interference and persistent smoke trends through algorithms;
    • Provide application specifications for areas near kitchens, corridors, and airflow zones;
    • Configure different alarm curves for different national standards;
    • Establish sensitivity calibration and sampling inspection mechanisms in mass production.

    CFS recommends that smoke detectors adopt photoelectric technology and insect-proof design to reduce the risk of false alarms at the source.

    Interconnection Design: One Alarm Triggers the Whole House

    The key value of a Hardwired Smoke Alarm lies in its ability to synchronize alarms from multiple devices via interconnected wiring. This is crucial for B2B project clients:

    • Bedroom alarms also trigger in the living room;
    • Basement alarms also trigger upstairs.
    • Create a unified alarm network within an apartment unit;
    • Hotels or dormitories can implement zoned interconnection according to project requirements;
    • Easier project acceptance and standardization.

    NFPA’s recommended placement for residential smoke detectors covers bedrooms, sleeping areas, and each floor. For Hardwired projects, the interconnection function improves alarm audibility, especially in scenarios with closed doors, floor separation, or late-night sleep.

    Project Implementation Recommendations:

    • Use hardwired interconnect signals;
    • Define the maximum number of interconnected alarms;
    • Define cable specifications and maximum wiring distance;
    • Add LED/buzzer differentiation between local and remote interconnected alarms;
    • Provide installation instructions and wiring diagrams to reduce the probability of incorrect on-site wiring. If customers wish to cover both the new construction and renovation markets, a dual-mode product with Hardwired + RF Interlinked can be designed: hardwired for new projects and RF interlinked for renovations of older buildings.
    hardwired smoke alarm manufacturer CFS SM11R4
    hardwired smoke alarm manufacturer CFS SM11R4

    Structural Design: Wiring Space, Terminal Safety and Installer-Friendly Mounting

    For 120V and 230V hardwired smoke alarm projects, the structure should be designed around wiring space, terminal safety distance, heat dissipation, and installer maintenance.

    Key structural features include:

    • Quick-release base;
    • Tamper-proof structure;
    • Terminal block space;
    • AC strong/weak current isolation;
    • Dustproof and insect-proof smoke chamber;
    • Buzzer sound outlet;
    • Test/mute button feel;
    • LED viewing angle;
    • Flame-retardant housing material;
    • Screw holes suitable for mass production.

    Hardwired smoke alarm manufacturer CFS supports customization in ABS, PVC, PC, HIPS, PP, and UV-resistant, as well as options for matte, glossy, frosted, and Pantone custom colors.

    Sacrificing wiring and heat dissipation space for an “ultra-thin appearance” is not recommended for real estate and engineering projects.  A compact housing is useful, but it should not sacrifice wiring space, heat dissipation or terminal accessibility. If electricians cannot install or service the unit easily, small structural issues will become high field service costs. Otherwise, small problems incur high costs on the project site.

    custom heat detector CFS heat tunel
    custom heat detector CFS heat tunel

    AC Powered Smoke Alarm with Battery Backup: Key Validation Before Mass Production

    Before mass production, an AC powered smoke alarm with battery backup should be verified as a safety device, not a feature item. We check AC-DC temperature rise, input protection, power ripple, EMC and surge protection, mains failure switching, low-battery threshold, buzzer output under low voltage, long-term aging, high-low temperature cycling, and backup battery storage life. These tests help reduce certification risk, field complaints, and unstable batch quality.

    How to Design an Interconnected Hardwired Smoke Alarm for Residential Projects

    An interconnected hardwired smoke alarm should be designed around wiring reliability and installer convenience. Before production, we verify the maximum number of linked alarms, wiring distance, cable specification, local/remote alarm indication, LED and buzzer logic, and incorrect wiring protection. For new buildings, hardwired interconnect offers better standardization. For renovations, hardwired + RF interlinked design can reduce rewiring cost while keeping all alarms synchronized.

    Hardwired Smoke Alarm Certification Strategy for North America, Europe and Australia

    Certification risk is decided before formal testing. The housing structure, PCB layout, optical chamber, firmware logic, rating label, user manual and installation method should be designed according to the target standard from the first engineering sample. For OEM/ODM projects, certification is not a label added after development. It affects the optical chamber, firmware threshold, power design, interconnect logic, housing material, rating label and installation manual from the first design review.

    Market

    Typical Standard / Requirement

    Engineering Focus

    North America

    UL 217 / UL 268 / NFPA 72

    Alarm response, nuisance alarm, installation, power backup

    Europe

    EN 14604 / CE / EMC / LVD / RoHS

    Electrical safety, EMC, smoke response, label and manual

    Australia

    AS 3786 / RCM

    Smoke alarm performance, electrical compliance, local marking

    The biggest mistake in Hardwired Smoke Alarm OEM/ODM projects is creating a prototype first and then applying for certification. The correct process should be:

    1. Target market identification;
    2. Standard path identification;
    3. Product structure finalization;
    4. Circuit and software pre-design according to standards;
    5. Engineering prototype testing;
    6. Pre-testing;
    7. Rectification;
    8. Formal certification;
    9. Mass production consistency control.
    hardwired smoke alarm manufacturer CFS battery test
    hardwired smoke alarm manufacturer CFS battery test

    For the North American market, focus on UL 217 / UL 268 / NFPA 72 requirements; for the European market, focus on EN 14604, CE, RoHS, etc.; for the Australian market, focus on AS 3786 / RCM, etc. Different standards have different requirements for alarm response, false alarm suppression, power supply, manual instruction, labeling, and installation methods.

    Our engineering work starts before the first sample. We review the target market, voltage input, battery backup, interconnect method, certification route and installation environment before freezing the PCB, housing and firmware design.

    OEM/ODM Customization Options for Hardwired Smoke Alarm Brands

    For OEM/ODM buyers, customization should not only change appearance. It should help the brand build a stable, certifiable and scalable product platform. For procurement managers, the customization scope should be confirmed early because it directly affects MOQ, NRE, tooling cost, certification samples and development schedule.

    Items

    Customizable Content

    B2B Value

    Development Scope

    Standard private label / firmware change / housing change / new platform

    Clarifies MOQ, NRE and development schedule

    Power Supply

    120V/ 230V AC + Battery Backup

    Compatible with target countries and project acceptance

    Communication

    Hardwired / RF / Wi-Fi / Zigbee

    Establish different product lines

    Structure

    Housing, base, terminal space, buttons

    Reduce installation and maintenance difficulty

    Brand

    Logo, Packaging, Instruction Manual, Barcode

    Private label sales

    Firmware

    Alarm logic, mute logic, low battery alert

    Reduce false alarms and after-sales complaints

    Certifications

    UL / EN / AS / CE / RCM pathways

    Shorten time-to-market

    Documentation

    Datasheet, user manual, wiring diagram, carton label, certification file

    Supports project bidding and market entry

    For private label projects, buyers should prepare or confirm the brand logo, target market, voltage rating, certification requirement, packaging language, user manual language, barcode format, installation diagram and importer information. These documents should be reviewed before artwork approval to avoid label, manual, customs or certification conflicts.

    Engineering Validation and Mass Production Quality Control

    For safety products, validation should not stop at functional testing. Before mass production, we check smoke sensitivity, sound pressure, AC-DC temperature rise, low-battery warning, interconnect distance, EMC performance, aging stability, optical chamber cleanliness, firmware version and packaging consistency. This helps reduce the gap between approved samples and delivered batches.

    hardwired smoke alarm manufacturer CFS
    hardwired smoke alarm manufacturer CFS

    Hardwired Smoke Alarm OEM/ODM Project Workflow

    The purpose of this workflow is to reduce the gap between approved samples and mass production quality.

    • Requirement review
    • Certification path confirmation
    • Electrical and structural design
    • Engineering sample
    • Pre-test and debugging
    • Pilot production
    • Firmware version and BOM freeze
    • Mass production approval
    • Final inspection and shipment
    • After-sales technical support

    Case Study: Developing a Scalable Hardwired Smoke Alarm Platform

    Instead of developing one isolated SKU, we recommended a shared product platform covering basic hardwired, interlinked and Wi-Fi/RF versions.

    Project Background

    The client is a brand owner selling fire safety products to residential developers and electrical contractors, targeting new residential buildings, apartments, and small commercial spaces. The client originally sold battery-operated smoke alarms but found in project tenders that many new residential projects preferred hardwired smoke alarms with battery backup and interconnect functions.

    The client’s requirements included:

    • 230V AC main power supply;
    • Backup battery;
    • Photoelectric smoke detection;
    • Wired linkage for multiple units;
    • Custom packaging available;
    • Modern design;
    • Future expansion to include a Wi-Fi version;
    • Target sales through both engineering and retail channels.

    Problem Diagnosis

    Initially, we didn’t provide a direct quote. Instead, we broke down the requirements based on the project:

    • Is this product for a new cabling project or a renovation of an existing building?
    • Does the customer require only AC powered?
    • Is the backup battery with 3, or 10 years?
    • Are a silence button, test button, low battery warning, and AC fault indicator required?
    • Does it need to maintain a consistent appearance with existing SKUs?

    We recommended a shared product platform instead of one isolated SKU, covering basic hardwired, hardwired interlinked and Wi-Fi/RF versions.

    Phase 1: Basic Hardwired Photoelectric Smoke Alarm

    • 230V AC input;
    • DC3V backup battery;
    • Photoelectric smoke chamber;
    • Local buzzer alarm;
    • Test / Silence button;
    • LED status indicator;
    • Low battery alarm;
    • AC fault indication;
    • Standard private label packaging.

    Phase 2: Hardwired Interlinked Smoke Alarm

    • Add linkage wiring;
    • Multiple units simultaneously alarm;
    • Differentiate between local alarm and remote linkage alarm status;
    • Define the maximum number of linkages.
    • Provide engineering wiring diagrams;
    • Provide installation instructions.

    Phase 3: Hardwired + Wi-Fi / RF Extended Version

    • Maintain the same structural platform;
    • Share some PCBs and housing;
    • Differentiate SKUs through different modules;
    • Reduce mold costs;
    • Facilitate customers in establishing high, medium, and low-end product lines.

    Project Results

    The end customer doesn’t receive a standalone product, but rather a sustainably scalable hardwired smoke alarm OEM/ODM platform:

    • Reduce redundant certification investment
    • Establish a high, medium, and low SKU product line
    • Shared structural platform reduces mold costs
    • Simultaneous coverage of engineering and retail channels
    • Future expansion to include Combo Smoke and CO Alarm

    This approach is more suitable for B2B customers than developing a standalone, low-cost product because it reduces redundant certification efforts, streamlines the supply chain, and allows the sales team a more comprehensive product portfolio.

    How to Choose a Hardwired Smoke Alarm OEM/ODM Manufacturer

    If you are looking for a hardwired smoke alarm OEM/ODM manufacturer , it is not only about comparing FOB unit prices. You should focus on verifying the following 8 aspects:

    • Do they have long-term manufacturing smoke and CO alarms?
    • Can provide a 120V/230V AC power supply design?
    • Can they provide AC+Battery backup power supply designs?
    • Can they support hardwired interconnect or hardwire+RF linkage solutions?
    • Do they have experience with photoelectric cavity and false alarm control?
    • Can they provide support for private labeling, packaging, manuals, labels, and barcodes?
    • Do they have consistency control processes for engineering prototypes, pilot production, and mass production?
    • Can they provide placement, wiring, and certification advice in the early stages of a project?

    The private label smoke alarm manufacturer’s process makes it suitable for long-term cooperation with brand owners and project customers.

    FAQ About Hardwired Smoke Alarm OEM/ODM Manufacturing

    Yes, but we don’t recommend simply using the same power supply solution. 120V and 230V involve differences in input protection, safety distances, certification testing, and labeling. The target country and certification path should be confirmed at the beginning of the project.

    Yes. A hardwired smoke alarm can use AC mains power with backup battery support, ensuring alarm operation during power failure and reducing project acceptance and maintenance risks.

    Yes. Hardwired interconnect allows one triggered alarm to activate other connected units, improving audibility across bedrooms, corridors, apartments, hotels, and multi-room residential projects.

    Yes. A basic hardwired version can serve project applications, while Wi-Fi or RF interlinked versions can support smart home, retail and renovation markets. The communication method should be confirmed before PCB and housing design.

    The key lies in the design of the photoelectric cavity, insect-proof structure, dust control, software algorithm, installation location instructions, and production calibration.

    Yes. We support logo, color box, rating label, barcode, carton mark, user manual and wiring diagram, aligned with certification, voltage, battery and target market requirements.

    The process includes requirement review, technical evaluation, engineering sample, pre-compliance testing, pilot production, certification support, mass production control and final shipment inspection.

    Summary

    A truly qualified Hardwired Smoke Alarm OEM/ODM Solution is not simply about connecting a smoke alarm to an AC power source. A Hardwired smoke alarm manufacturer uses a complete system including power reliability, backup batteries, photoelectric detection, control false alarms, hardwired linkage, certification pathways, structural installation, and the mass production consistency.

    A good hardwired smoke detector OEM supplier not only provides products but also helps reduce certification risks, minimize after-sales complaints, shorten time-to-market, and build a sustainably scalable product line.

    A good photoelectric hardwired smoke alarm should have a stable power supply, unified linkage, easy project acceptance, suitability for mass installations, and lower long-term maintenance costs.

    Related Products

    SM11HW WIFI Photoelectric Smoke Alarm

    Lifetime: 10 years

    SM11R8 Wireless Interlinked Photoelectric Smoke Alarm

    Lifetime: 10 years

    SM04 Standalone Photoelectric Mini Smoke Alarm

    Lifetime: 10 years

    SM31R Wireless Interlinked Photoelectric Smoke Alarm

    Lifetime: 10 years

    SM22 Hardwire Photoelectric Smoke Alarm with DC3V backup Battery

    Lifetime: 10 years

    SM11R4 Wireless Interlinked Photoelectric Smoke Alarm

    Lifetime: 3 or 10 years, cuztomziation avaliable

    SM17R Wireless Interlinked Photoelectric Smoke Alarm

    Lifetime: 10 years

    SM02 Standalone Photoelectric Mini Smoke Alarm

    Lifetime: 10 years

    SM17W WIFI Photoelectric Smoke Alarm

    Lifetime: 3 or 10 years, Customizable

    Related Articles